Release Time:2019/06/01 Component maintenance Browsing Times:877
Firstly, turn off the whole machine power.
Remove Old Part:
Install New Part:
Note: the laser head will find home(top left corner) during boot up, if the controller board have not been set as factory setting, the laser head will homing to other corner then cause the accident. So check the setting of the board before putting back the connector of AXIS X and Y.
Open the vendor setting windows: menu bar(top left corner)>>File(F)>>vendor setting>>password:rd8888.
Read the setting of the board by the “Read” button, the progress bar will become blue once read successfully, like below.
Check the breath of X, it should be 900mm for nova35 for instance.
If yes, the controller board is in factory setting, reboot the machine and done after putting back the connector of AXIS X and Y.
Note: if the breadth is not correct, please contact with our tech team: tech@thunderlaser.com.
End.